8. Instruments
The instruments in RobotWin Studio behave like real ones: the oscilloscope’s probe loads the circuit, the multimeter’s fuse can blow, the bench supply goes into current limit. Most of them are in the tabs at the bottom of the Devre (circuit) page.

Oscilloscope
The Osiloskop (oscilloscope) tab is a 4-channel digital oscilloscope.
Attaching a probe
- Start the simulation (F5).
- Click the wire you want to measure; the probe goes on the first free channel.
- For a particular channel, right-click the wire and choose … → osiloskop CH1 … CH4. A probe can be attached before the simulation too; it measures once the simulation starts.
Settings
| Section | Settings |
|---|---|
| Horizontal | Time/div, position, roll mode |
| Channel | Volts/div, position, coupling (DC / AC / GND), probe 1× / 10×, 20 MHz bandwidth limit, invert, current probe |
| Trigger | Mode (Auto, Normal, Tek (single)), source (1–4), slope (rising / falling), level, holdoff |
| Maths | 1+2 or 1−2 |
| Buttons | RUN / STOP, TEK (single), AUTOSET, cursors |
With Prob yüklemesi (probe loading) on, the probe connects to the circuit as 1 MΩ ∥ 110 pF (1×) or 10 MΩ ∥ 12 pF (10×); in high-impedance circuits you see how the measurement disturbs the circuit.
Automatic measurements: maximum, minimum, peak-to-peak, amplitude, mean, RMS, period, frequency, duty cycle, rise and fall time.
Multimeter
The Multimetre (multimeter) tab is a 6000-count, true-RMS, autoranging handheld multimeter.
- Choose Prob multimetre (kırmızı / siyah uçlar) (probe multimeter: red / black leads) in the Ölçü aleti (instrument) list.
- Right-click a wire and choose Multimetre kırmızı ucu → … (red lead), and on another wire Multimetre siyah ucu (COM) → … (black lead).
- Pick the function with the rotary switch: DC V, AC V, DC A, AC A, Ω, continuity (beeps below 30 Ω), diode, capacitance, frequency + duty cycle.
Things to watch (as on a real multimeter):
- To measure current the multimeter goes in series with the circuit. The mA input has a 440 mA fuse, the A input an 11 A fuse; too much current blows the fuse.
- The voltage input loads the circuit with 10 MΩ.
- Trying to measure resistance in a live circuit gives a warning.
You can also put a multimeter into the circuit as a part: Dijital Multimetre (6000 sayım) (digital multimeter, 6000 counts) or Multimetre (akım, mA girişi) (multimeter, current, mA input). Then pick that part in the Ölçü aleti (instrument) list.
Bench power supply
The library has Lab. Güç Kaynağı 0-30 V 3 A and Lab. Güç Kaynağı 5 V / 100 mA (bench supplies).
- CV / CC: gives the set voltage; at the current limit it switches to constant current (CC). A short circuit does not burn your circuit: the supply goes to CC.
- OVP: over-voltage protection; when it trips it switches the output off.
- It has an output switch; the supply cannot sink current (it only sources).
Using the 5 V / 100 mA supply when first trying a new circuit stops mistakes from burning parts.
Adjustable AC/DC power supply
Ayarlanabilir AC/DC Kaynak 0-30 V DC / 0-24 V AC, 3 A (adjustable AC/DC supply) gives one of three outputs, picked with Çıkış tipi (output type) in the inspector:
| Output | What it gives |
|---|---|
| DC | A set voltage (CV) with a current limit (CC), like a bench supply |
| AC | A sine: RMS voltage, frequency and phase are set (peak = √2 × RMS; 17 V peak for 12 V~) |
| DC + AC | An AC ripple on top of the DC voltage, like a rectified supply or a noisy rail |
- On AC the current limit holds in both directions: the supply sources and sinks current and holds the peak current at the limit.
- OVP looks at the voltage’s absolute value.
- The symbol shows the setting, e.g.
12V~or12+1~. The circuit’s voltage readouts print the RMS value of AC nets withV~; the multimeter’s AC voltage range measures true RMS too. The simulation report gives the true RMS voltage and current over whole cycles.
Presets: AC Kaynak 12 V RMS 50 Hz (a transformer’s output; bridge rectifier and capacitor experiments), AC Kaynak 24 V RMS 60 Hz (industrial control voltage), Şebeke 230 V RMS 50 Hz (mains, 325 V peak) and DC 12 V + 1 V RMS dalgalanma 100 Hz (12 V DC with 1 V RMS ripple; regulator and filter experiments).
Tolerances
Real parts are not at their labelled values. The Simülasyon: parça toleransı (simulation: part tolerance) option in the right panel:
| Mode | What happens |
|---|---|
| Nominal (ideal değerler) (ideal values) | Every part exactly at its label value |
| Gerçekçi (sabit tohum) (realistic, fixed seed) | Each part takes a fixed real value within its tolerance (resistor ±5 %, ceramic ±10 %, electrolytic −20/+80 %, hFE, LED Vf…). The same Tohum (seed) always gives the same board; Yeni (new) draws another board. |
| Monte Carlo (N koşu) (N runs) | Use the Monte Carlo tab below to see the spread |
Monte Carlo
The Monte Carlo tab runs the circuit N times, drawing the tolerances anew each time, and measures a net you choose.
- Choose the net and the measure (final value, mean, maximum, minimum, peak-to-peak, RMS).
- Press Çalıştır (run) (İptal cancels).
- The result appears as a histogram with the smallest and largest values, the runs they came from and the spread.
Board firmware does not run during Monte Carlo; the analog circuit is examined.
Fault finding
The Arıza tespiti (fault finding) tab finds design mistakes in your circuit.
- Analiz et (analyse): scans the circuit by rules: supply short, LED without a resistor, reversed LED, reversed electrolytic capacitor, floating inputs, missing ground, driving a motor straight from a pin, missing flyback diode, regulator problems…
- Simülasyonda canlı (live in the simulation): watches during simulation how close parts get to their limits, whether the battery is overloaded, whether the supply enters CC mode, and the multimeter fuse.
- Neden? (why?): explains why a part burned.
Measuring in the world
On the Dünya (world) page:
- The Kablolar ve ölçümler (cables and measurements) tab below shows each cable’s current, power and load percentage.
- With the cable tool, the live voltage of the pin under the mouse is shown.
- The selected object’s inspector has a Canlı ölçüm (live measurement) section.
Recording
Dosya → Simülasyon kaydını kaydet (.rwsim)… (File → save simulation recording) stores the measurement channels, events and serial output with the project. Opening the recording brings the waveforms back on the oscilloscope and the events in the log.
← Previous: 7. World · Contents · Next: 9. Keyboard shortcuts →